IONIX® 1'' UHV Circular Sputtering Source

 

IX1U is the smallest IONIX® ultrahigh vacuum magnetron sputtering source with target diameter of 25.4 mm (1'') used in thin film research and development. The target thickness can vary from 1 to 3 mm for non-ferromagnetic targets. The IX1U features indirect cooling of the target and a sliding anode allowing easy adjustment of the dark space gap when varying target thickness.

Optionally a magnet array for magnetic target materials (Fe 0.9 mm, Ni 3 mm with profiles) is available or can be retrofitted later.

Features

  • internal mounting with CF interface
  • target diameter 1" (25.4 mm)
  • targets 1 - 3 mm thick, non-magnetic
  • magnetic targets Ni 3 with profiles, Fe 0.9 mm thick
  • indirectly cooled targets
  • magnet array completely isolated from cooling water
  • for DC, AC, RF and pulsed operation
  • water tubes Ø6xØ4 mm

Technical data

Target   Dimensions  
form circular/planar diameter 44 mm
diameter 1" (25,4 mm) ± 0,1mm height 64 mm (86 mm)
thickness 1 - 3 mm Mounting tube Ø1" x 300 mm
cooling indirect ***
  DN 16 CF
Working pressure argon Construction materials stainless steel
OFHC - type copper
Al2O3
nonmagnetic targets 6x10-3- 5x10-2 mbar Cooling water  
best performance 5x10-3-1,5x10-2mbar flow 1 l / (min x kW)
Typical rates   max. inlet temperature ≤ 30°C
Cu, 7 cm distance 15 Å/s @ 100W max. pressure ≤ 2 bar open drain
    Ø tubing Ø6xØ4 mm PTFE
Electrical specifications   Magnet array permanent SmCO
max. power, watts DC 100 W DC max. temperature 200°C
max. power, watts RF 100 W RF Accessories and options  
max. current DC 5 A - quick coupling f/t - ±45° flexible tilt
max. voltage DC 1200 V - ferromagnetic materials - 40° insitu tilt
connector DC type N  - gas inlet option - chimney option
connector RF type 7/16 ** - pneumatic shutter - flange mounting
* This value refers to the magnetron itself. The maximum power is determined by the target material and
its bonding or clamping technique.
** RF-Version requires special connector and/or installation. More details on request.
*** Direct cooling on request.

We reserve the right for technical changes in design and specifications without notice or obligations.

Mounting options

  • Chimney
  • +/- 45° tilt or 40° insitu-tilt
  • Pneumatic, electric or manual shutter
  • Gas distribution
  • Quick coupling feedtrough
  • Z-Manipulator
  • Flange mounting option

Dimensions

Dimensions for IX1U flange assembly consisting of sputtering source with chimney, tilt, pneumatic shutter and gas distribution on DN63CF

 

 

 

 

 

 

 

 

 

Notwendige Cookies helfen dabei, eine Webseite nutzbar zu machen, indem sie Grundfunktionen wie Seitennavigation und Zugriff auf sichere Bereiche der Webseite ermöglichen. Die Webseite kann ohne diese Cookies nicht richtig funktionieren. Eventuell werden in den Cookies Informationen über Ihre Daten gespeichert, die bei Ihren nächsten Besuchen aufgerufen werden können. Die in einem Cookie abgelegten Daten vereinfachen z.B. die Suche im Internet. Wir verwenden diese Cookies nicht um personenbezogene Daten zu verwenden. Informationen über die Verwendung der Cookies oder um diese auszuschließen, sollte Sie die entsprechenden Browsereinstellungen anpassen.